Squelch Application
Availability
SkySweeper STD : YES
SkySweeper STD+ : YES
SkySweeper PRO : YES
The squelch application is used for noise squelch. When the average signal power exceeds the defined threshold, the block input is connected to the output, otherwise the output is muted The time information (about when the squelch has been in active state) is written to the text based log file (if defined).
Parameters
Squelch
If the squelch is enabled, the block is active. The threshold for the noise squelch is set manually. There is also a power indicator showing the current signal power. The log file is used to store the time and date information about when the squelch has been in active state. If ‘None’ is selected as log file name, the log file is not generated.
Sample Count
This shows the total number of signal samples, which are connected from the squelch input to it’s output.